Dynamic modeling of two-phase exchangers applied to refrigeration units controlled by an advanced control

An accurate control of fluids flow is essential in any refrigeration system. As the conventional Proportional-Integral-Derivative (PID) control with invariable parameters can lead to unsatisfactory performance because of the variation of refrigeration unit parameters under disturbances, the aim of the work presented here is to develop a method for using Predictive Functional Control (PFC) to regulate the evaporator superheat, the condensing pressure and the cooling capacity on a variable-speed refrigeration system. Using a predictive controller requires to predic future change at the output of the process. This prediction is based on an internal model used as known model. By assuming that the behaviour of refrigerating machine heat exchangers can be represented using a first-order model, the implementation of PFC requires only three parameters: gain, time constant and time delay. In order to determine these parameters an original method has been developed which is based on the physical modelling of the machine. Physical models for different types of evaporator, condenser, compressor or expansion valve have been established to quantify heat transfer and refrigerant flow rate in these components. The control system created has been incorporated into an industrial programmable logic controller and used for experiments on two different refrigerating machines: the first one is composed of two shell and tube heat exchangers and a reciprocating compressor, whereas the second one is composed of a plate evaporator, a finned-tube condenser and a screw compressor. The tests performed show that PFC controller succeed in maintaining a precise chilled liquid temperature.

Data and Resources

Additional Info

Field Value
Source https://theses.hal.science/tel-00679702
Author Fallahsohi, Hossein
Maintainer CCSD
Last Updated May 24, 2026, 11:26 (UTC)
Created May 24, 2026, 11:26 (UTC)
Identifier NNT: 2011ISAL0034
Language fr
Rights https://about.hal.science/hal-authorisation-v1/
contributor Ampère (AMPERE) ; École Centrale de Lyon (ECL) ; Université de Lyon-Université de Lyon-Université Claude Bernard Lyon 1 (UCBL) ; Université de Lyon-Institut National des Sciences Appliquées de Lyon (INSA Lyon) ; Université de Lyon-Institut National des Sciences Appliquées (INSA)-Institut National des Sciences Appliquées (INSA)-Centre National de la Recherche Scientifique (CNRS)-Institut National de Recherche pour l’Agriculture, l’Alimentation et l’Environnement (INRAE)
creator Fallahsohi, Hossein
date 2011-04-26T00:00:00
harvest_object_id b7ec6838-77b9-40d5-826e-de4504052313
harvest_source_id 3374d638-d20b-4672-ba96-a23232d55657
harvest_source_title test moissonnage SELUNE
metadata_modified 2026-05-23T00:00:00
set_spec type:THESE