Design study of a Compton camera for prompts-gamma imaging during ion beam therapy

Ion beam therapy is an innovative radiotherapy technique using mainly carbon ion and proton irradiations. Its aim is to improve the current treatment modalities. Because of the sharpness of the dose distributions, a control of the dose if possible in real time is highly desirable. A possibility is to detect the prompt gamma rays emitted subsequently to the nuclear fragmentations occurring during the treatment of the patient. In a first time two different Compton cameras (double and single scattering) have been optimised by means of Monte Carlo simulations. The response of the camera to a photon point source with a realistic energy spectrum was studied. Then, the response of the camera to the irradiation of a water phantom by a proton beam was simulated. It was first compared with measurement performed with small-size detectors. Then, using the previous measurements, we evaluated the counting rates expected in clinical conditions. In the current set-up of the camera, these counting rates are pretty high. Pile up and random coincidences will be problematic. Finally we demonstrate that the detection system is capable to detect a longitudinal shift in the Bragg peak of +or- 5 mm, even with the current reconstruction algorithm.

Data and Resources

Additional Info

Field Value
Source https://theses.hal.science/tel-00934715
Author Richard, Marie-Hélène
Maintainer CCSD
Last Updated May 7, 2026, 07:34 (UTC)
Created May 7, 2026, 07:34 (UTC)
Identifier NNT: 2012LYO10124
Language en
Rights https://about.hal.science/hal-authorisation-v1/
contributor Centre de Recherche en Acquisition et Traitement de l'Image pour la Santé (CREATIS) ; Université Claude Bernard Lyon 1 (UCBL) ; Université de Lyon-Université de Lyon-Institut National des Sciences Appliquées de Lyon (INSA Lyon) ; Université de Lyon-Institut National des Sciences Appliquées (INSA)-Institut National des Sciences Appliquées (INSA)-Université Jean Monnet - Saint-Étienne (UJM) ; Université Jean Monnet (EPSCPE) (UJM EPE)-Université Jean Monnet (EPSCPE) (UJM EPE)-Institut National de la Santé et de la Recherche Médicale (INSERM)-Centre National de la Recherche Scientifique (CNRS)
creator Richard, Marie-Hélène
date 2012-09-04T00:00:00
harvest_object_id c84cfa3b-d3f4-48d2-a9a7-8a5917e13b2d
harvest_source_id 3374d638-d20b-4672-ba96-a23232d55657
harvest_source_title test moissonnage SELUNE
metadata_modified 2026-04-23T00:00:00
set_spec type:THESE