Impact of a nitrogen plasma discharge on the polyurethane catheters stability

Currently, sterilization methods are not universal, which implies the development of innovative processes. Electric discharge in atmospheric pressure (plasma discharge) is one of the way that seems both interesting and attractive to be explored in the field of sterilization of plastic materials for medical use. Indeed; plasma discharge combines altogether fast sterilization process with low cost and a non toxic method applicable to thermo sensitive materials. One point that must be verified is that the sterilization process does not modify the surface nor the structure of the re-usable medical devices in order to preserve their functionality. Hence, the impact of the treatment of plasma discharge on biomaterials seems less important than the one of other sterilization methods. Our goal is to study the stability of polymer materials such as polyurethane, very much used in biomedical field, after a plasma discharge sterilization, already developed and optimized by the Laboratoire des Gaz et des Plasmas (Orsay, France). Those polymers are often used for the manufacturing of medical systems (cardiac assist devices, pacemakers, catheters, endoscopes, endotracheal and oxygenation tubes, ...) because of their good mechanical, physical, chemical and biocompatible properties. In this study, we have been interested in the possible modifications of Pellethane®-based tubes treated by plasma discharge. Those modifications can appear in two levels : on the properties of the material and on its composition. That is why different analytical techniques have been used, such as DSC, ATG, GPC for the bulk characterization as well as FTIR-ATR, mouillability measurements, SEM and optical microscopy for the surface characterization. Moreover, the variation of the composition has been studied by RP-HPLC in order to evaluate the presence of extractibles and their possible diffusion, which is an important point towards their possible cytotoxicity. At last, we have evaluated the impact of the different physico-chemical properties on abacterial strain adhesion (Staphylococcus aureus), very much involved in nosocomial infections.

Data and Resources

Additional Info

Field Value
Source https://theses.hal.science/tel-00808309
Author Mrad, Omar
Maintainer CCSD
Last Updated May 11, 2026, 16:21 (UTC)
Created May 11, 2026, 16:21 (UTC)
Identifier tel-00808309
Language fr
Rights https://about.hal.science/hal-authorisation-v1/
contributor Groupe matériaux et santé ; Université Paris-Sud - Paris 11 (UP11)
creator Mrad, Omar
date 2007-03-26T00:00:00
harvest_object_id 0923409c-5c3a-48fe-9cdc-8d0b28ed9c32
harvest_source_id 3374d638-d20b-4672-ba96-a23232d55657
harvest_source_title test moissonnage SELUNE
metadata_modified 2023-04-09T00:00:00
set_spec type:THESE