National absorbed dose to water references for radiotherapy medium energy X-rays by water calorimetry

LNE-LNHB current references for medium energy X-rays are established in terms of air kerma. Absorbed dose to water, which is the quantity of interest for radiotherapy, is obtained by transfer dosimetric techniques following a methodology described in international protocols. The aim of the thesis is to establish standards in terms of absorbed dose to water in the reference protocol conditions by water calorimetry. The basic principle of water calorimetry is to measure the absorbed dose from the rise in temperature of water under irradiation. A calorimeter was developed to perform measurements at a 2 cm depth in water according to IAEA TRS-398 protocol for medium energy x-rays. Absorbed dose rates to water measured by calorimetry were compared to the values established using protocols based on references in terms of air kerma. A difference lower than 2.1% was reported. Standard uncertainty of water calorimetry being 0.8%, the one associated to the values from protocols being around 3.0%, results are consistent considering the uncertainties. Thanks to these new standards, it will be possible to use IAEA TRS-398 protocol to determine absorbed dose to water: a significant reduction of uncertainties is obtained (divided by 3 by comparison with the application of the IAEA TRS-277 protocol). Currently, none of the counterparts’ laboratories own such an instrument allowing direct determination of standards in the reference conditions recommended by the international radiotherapy protocols.

Data and Resources

Additional Info

Field Value
Source https://theses.hal.science/tel-00763348
Author Perichon, Nicolas
Maintainer CCSD
Last Updated June 1, 2026, 00:20 (UTC)
Created June 1, 2026, 00:20 (UTC)
Identifier NNT: 2012PA112153
Language fr
Rights https://about.hal.science/hal-authorisation-v1/
contributor Laboratoire National Henri Becquerel (CEA, LIST) (LNHB (CEA, LIST)) ; Département Métrologie Instrumentation & Information (CEA, LIST) (DM2I (CEA, LIST)) ; Laboratoire d'Intégration des Systèmes et des Technologies (LIST (CEA)) ; Direction de Recherche Technologique (CEA) (DRT (CEA)) ; Commissariat à l'énergie atomique et aux énergies alternatives (CEA)-Commissariat à l'énergie atomique et aux énergies alternatives (CEA)-Direction de Recherche Technologique (CEA) (DRT (CEA)) ; Commissariat à l'énergie atomique et aux énergies alternatives (CEA)-Commissariat à l'énergie atomique et aux énergies alternatives (CEA)-Université Paris-Saclay-Laboratoire d'Intégration des Systèmes et des Technologies (LIST (CEA)) ; Direction de Recherche Technologique (CEA) (DRT (CEA)) ; Commissariat à l'énergie atomique et aux énergies alternatives (CEA)-Commissariat à l'énergie atomique et aux énergies alternatives (CEA)-Direction de Recherche Technologique (CEA) (DRT (CEA)) ; Commissariat à l'énergie atomique et aux énergies alternatives (CEA)-Commissariat à l'énergie atomique et aux énergies alternatives (CEA)-Université Paris-Saclay
creator Perichon, Nicolas
date 2012-09-10T00:00:00
harvest_object_id b4329c4f-3d6f-4ec4-9eb4-3444cc10e8f9
harvest_source_id 3374d638-d20b-4672-ba96-a23232d55657
harvest_source_title test moissonnage SELUNE
metadata_modified 2026-03-30T00:00:00
set_spec type:THESE