A Biomechanical Evaluation of Bicortical Metal Screw Fixation Versus Absorbable Interference Screw Fixation After Coracoid Transfer for Anterior Shoulder Instability

Purpose: The purpose was to evaluate the load to failure of 2 coracoid fixation techniques after transfer of the coracoid to the anterior glenoid neck. Methods: Ten cadavers (mean age, 87 years; range, 74 to 96 years) underwent the Bristow conjoined tendon tenodesis technique as described by Boileau et al. (bioabsorbable interference screw fixation of a coracoid bone plug) in 1 shoulder and the Latarjet-Patte coracoid transfer popularized by Walch (fixation with 2 screws through a larger piece of the coracoid) in the opposite shoulder. The force on the conjoined tendon required to pull the coracoid off of the anterior glenoid was recorded, along with the mode of construct failure. Results: The median ultimate failure load was 110 N (range, 35 to 170 N) in the interference screw group and 202 N (range, 95 to 300 N) in the bicortical screw group (P .002). The mode of failure of the interference screw technique was complete avulsion of the bone plug from the socket in 6 cases (60%) and fracture of the bone plug in 4 (40%). The mode of failure of the bone block technique was a vertical fracture through both screw holes in 7 cases (70%), a horizontal fracture through the distal screw hole in 2 (20%), and an intratendinous rupture of the conjoined tendon in 1 (10%). Conclusions: Fixation of a coracoid bone block to the anterior glenoid neck with 2 bicortical metal screws is stronger than fixation of a coracoid bone plug with an absorbable interference screw. Clinical Relevance: These data may influence surgeons' decisions regarding coracoid fixation as well as postoperative rehabilitation after coracoid transfer.

Data and Resources

Additional Info

Field Value
Source ISSN: 0749-8063
Author Weppe, Florent, Magnussen, Robert A., Lustig, Sebastien, Demey, Guillaume, Neyret, Philippe, Servien, Elvire
Maintainer CCSD
Last Updated May 5, 2026, 12:39 (UTC)
Created May 5, 2026, 12:39 (UTC)
Identifier hal-00985221
Language en
contributor Service de Chirurgie Orthopédique [Centre Albert Trillat] ; Centre Albert Trillat [Hôpital de la Croix-Rousse - HCL] ; Hôpital de la Croix-Rousse [CHU - HCL] ; Hospices Civils de Lyon (HCL)-Hospices Civils de Lyon (HCL)-Hôpital de la Croix-Rousse [CHU - HCL] ; Hospices Civils de Lyon (HCL)-Hospices Civils de Lyon (HCL)
creator Weppe, Florent
date 2011-01-01T00:00:00
harvest_object_id 10f3c1ab-d81e-4b4f-903c-9a3855809c94
harvest_source_id 3374d638-d20b-4672-ba96-a23232d55657
harvest_source_title test moissonnage SELUNE
metadata_modified 2024-12-03T00:00:00
relation info:eu-repo/semantics/altIdentifier/doi/10.1016/j.arthro.2011.03.074
set_spec type:ART