Comparison of linear and non-linear soft tissue models with post-operative CT scan in maxillofacial surgery

A Finite Element model of the face soft tissue is proposed to simulate the morphological outcomes of maxillofacial surgery. Three modelling options are implemented: a linear elastic model with small and large deformation hypothesis, and an hyperelastic Mooney-Rivlin model. An evaluation procedure based on a qualitative and quantitative comparison of the simulations with a post-operative CT scan is detailed. It is then applied to one clinical case to evaluate the differences between the three models, and with the actual patient morphology. First results shows in particular that for a “simple” clinical procedure where stress is less than 20%, a linear model seams sufficient for a correct modelling.

Data and Resources

Additional Info

Field Value
Source ISSN: 0302-9743
Author Chabanas, Matthieu, Payan, Yohan, Marecaux, Christophe, Swider, Pascal, Boutault, Franck
Maintainer CCSD
Last Updated May 11, 2026, 06:28 (UTC)
Created May 11, 2026, 06:28 (UTC)
Identifier hal-00081939
Language en
Rights https://about.hal.science/hal-authorisation-v1/
contributor Techniques de l'Ingénierie Médicale et de la Complexité - Informatique, Mathématiques et Applications, Grenoble - UMR 5525 (TIMC-IMAG) ; Université Joseph Fourier - Grenoble 1 (UJF)-Institut polytechnique de Grenoble - Grenoble Institute of Technology (Grenoble INP)-VetAgro Sup - Institut national d'enseignement supérieur et de recherche en alimentation, santé animale, sciences agronomiques et de l'environnement (VAS)-Centre National de la Recherche Scientifique (CNRS)
creator Chabanas, Matthieu
date 2004-05-11T00:00:00
harvest_object_id 70ff8cae-0164-407b-9906-990befe1569b
harvest_source_id 3374d638-d20b-4672-ba96-a23232d55657
harvest_source_title test moissonnage SELUNE
metadata_modified 2025-10-22T00:00:00
relation info:eu-repo/semantics/altIdentifier/arxiv/physics/0606218
set_spec type:ART