@prefix dcat: <http://www.w3.org/ns/dcat#> .
@prefix dct: <http://purl.org/dc/terms/> .
@prefix foaf: <http://xmlns.com/foaf/0.1/> .
@prefix vcard: <http://www.w3.org/2006/vcard/ns#> .
@prefix xsd: <http://www.w3.org/2001/XMLSchema#> .

<https://rec.harvest-normandie.data4citizen.com/dataset/oai-hal-tel-00768495v1> a dcat:Dataset ;
    dct:description """
              The aim of the study was to assess the feasibility of CT based 3D analysis of degenerated aortic bioprostheses to make easier their morphological assessment. This could be helpful during regular follow-up and for case selection, improved planning and mapping of valve-in-valve procedure. The challenge was represented by leaflets enhancement because of highly noised CT images. Contrast-enhanced ECG-gated CT scan was performed in patients with degenerated aortic bioprostheses before reoperation (in-vivo images). Different methods for noise reduction were tested and proposed. 3D reconstruction of bioprostheses components was achieved using stick based region segmentation methods. After reoperation, segmentation methods were applied to CT images of the explanted prostheses (ex-vivo images). Noise reduction obtained by improved stick filter showed best results in terms of signal to noise ratio comparing to anisotropic diffusion filters. All segmentation methods applied to in-vivo images allowed 3D bioprosthetic leaflets reconstruction. Explanted bioprostheses CT images were also processed and used as reference. Qualitative analysis revealed a good concordance between the in-vivo images and the bioprostheses alterations. Results from different methods were compared by means of volumetric criteria and discussed. ECG-gated CT images of aortic bioprostheses need a preprocessing to reduce noise and artifacts in order to enhance prosthetic leaflets. Stick region based segmentation seems to provide an interesting approach for the morphological characterization of degenerated bioprostheses.
            """ ;
    dct:identifier "tel-00768495" ;
    dct:issued "2026-05-29T13:52:52.401028"^^xsd:dateTime ;
    dct:language "fr" ;
    dct:modified "2026-05-29T13:52:52.401036"^^xsd:dateTime ;
    dct:publisher <https://rec.harvest-normandie.data4citizen.com/organization/cce9db95-46d9-4dc2-84b6-764215d0a002> ;
    dct:title "Morphological analysis of degenerated aortic valve bioprostheses by CT scan images segmentation" ;
    dcat:contactPoint [ a vcard:Organization ;
            vcard:fn "CCSD" ] ;
    dcat:distribution <https://rec.harvest-normandie.data4citizen.com/dataset/oai-hal-tel-00768495v1/resource/0e7ac701-5700-4f0e-99de-4e8243325f45> ;
    dcat:keyword "biovalves",
        "infoeu-reposemanticsdoctoralthesis",
        "scanographie-helicoidale",
        "sdvibimalife-sciences-q-biobioengineeringimaging",
        "sdvmhepchilife-sciences-q-biohuman-health-and-pathologysurgery",
        "sdvmhepcsclife-sciences-q-biohuman-health-and-pathologycardiology-and-cardiovascular-system",
        "spisignalengineering-sciences-physicssignal-and-image-processing",
        "techniques-numeriques",
        "theses",
        "tomodensitometrie-helicoidale-a-faisceau-conique",
        "traitement-dimages",
        "valve-de-laorte" ;
    dcat:landingPage <https://theses.hal.science/tel-00768495> .

<https://rec.harvest-normandie.data4citizen.com/dataset/oai-hal-tel-00768495v1/resource/0e7ac701-5700-4f0e-99de-4e8243325f45> a dcat:Distribution ;
    dct:format "HTML" ;
    dct:issued "2026-05-29T13:52:52.441341"^^xsd:dateTime ;
    dct:modified "2026-05-29T13:52:52.357566"^^xsd:dateTime ;
    dct:title "Morphological analysis of degenerated aortic valve bioprostheses by CT scan images segmentation" ;
    dcat:accessURL <https://theses.hal.science/tel-00768495> .

<https://rec.harvest-normandie.data4citizen.com/organization/cce9db95-46d9-4dc2-84b6-764215d0a002> a foaf:Agent ;
    foaf:name "test_moissonnage_selune" .

<https://theses.hal.science/tel-00768495> a foaf:Document .

