    dct:description """
              The aim of this preliminary study was to determine the accuracy of CT-scan to locate the femoral head centre. METHODS:  Eleven dried femurs were included for study. Three techniques were compared to determine femoral head centre (FHC) location: CT-scan, Motion Analysis and Faro-Arm. Markers were stuck on each femur to create a system of coordinates. Femurs lied on their posterior parts (bicondylar plane). Several points around the femoral head were palpated (Motion Analysis and Faro-Arm) or determined (Amira software for CT-scans). By a least-square regression method, the FHC location in 3D was defined for each technique. RESULTS:  The results of the FHC location determined by the CT-scan technique were compared with those measured by the faro-arm and the Motion Analysis techniques. The coordinates (X, Y, Z) of the FHC were compared between the three methods, and no statistical difference was found (p = 0.99). In a 3D plot, this gave a mean difference of 1.3 mm. The mean radius of the femoral head was of 22.5 mm (p = 0.6). CONCLUSIONS:  CT-scan is as accurate and reliable as gold-standard techniques (motion and faro-arm). Locating FHC before and after hip arthroplasty would allow hip surgeons to determine and compare 3D orientation of the upper-end of femur: offset, height and anteversion.
            """ ;
    dct:identifier "hal-00854135" ;
    dct:issued "2026-05-10T00:39:58.181657"^^xsd:dateTime ;
    dct:language "en" ;
    dct:modified "2026-05-10T00:39:58.181663"^^xsd:dateTime ;
    dct:publisher <https://rec.harvest-normandie.data4citizen.com/organization/cce9db95-46d9-4dc2-84b6-764215d0a002> ;
    dct:title "An evaluation of CT-scan to locate the femoral head centre and its implication for hip surgeons" ;
    dcat:contactPoint [ a vcard:Organization ;
            vcard:fn "CCSD" ] ;
    dcat:distribution <https://rec.harvest-normandie.data4citizen.com/dataset/oai-hal-hal-00854135v1/resource/c30b23d9-4a6a-4e7b-b5ec-1bd4e6b28392> ;
    dcat:keyword "anatomie",
        "femur",
        "hanche",
        "infoeu-reposemanticsarticle",
        "journal-articles",
        "sdvmhepahalife-sciences-q-biohuman-health-and-pathologytissues-and-organs-q-bioto" ;
    dcat:landingPage <ISSN:%200930-1038> .

<ISSN:%200930-1038> a foaf:Document .

<https://rec.harvest-normandie.data4citizen.com/dataset/oai-hal-hal-00854135v1/resource/c30b23d9-4a6a-4e7b-b5ec-1bd4e6b28392> a dcat:Distribution ;
    dct:format "HTML" ;
    dct:issued "2026-05-10T00:39:58.190493"^^xsd:dateTime ;
    dct:modified "2026-05-10T00:39:58.171681"^^xsd:dateTime ;
    dct:title "An evaluation of CT-scan to locate the femoral head centre and its implication for hip surgeons" ;
    dcat:accessURL <https://hal.science/hal-00854135> .

<https://rec.harvest-normandie.data4citizen.com/organization/cce9db95-46d9-4dc2-84b6-764215d0a002> a foaf:Agent ;
    foaf:name "test_moissonnage_selune" .